学科分类
/ 1
11 个结果
  • 简介:AbstractPurpose:This study was designed to compare the clinical efficacy of "8" and "0" wire fixation systems combined with double-head cannulated compression screws or Kirschner wires for the treatment of transverse patellar fractures.Methods:From September 2011 to September 2018, patients with closed transverse patellar fractures treated with a double-head compression screw or Kirschner wire were included and analyzed retrospectively. Patients with patellar fractures combined with distal femoral fractures, tibial plateau fracture or preoperative lower limb dysfunction were excluded. The patients treated with the "8" tension band wire fixation system and Kirschner wire were taken as Group A; those treated with the "0" fixation system and Kirschner wire were taken as Group B; those treated with the "8" fixation system and double-head cannulated compression screw were taken as group C; and those treated with the "0" fixation system and double-head cannulated compression screw were taken as group D. Six weeks and one year after the operation and every month from the third month after the operation until the fractures healed, an X-ray examination was performed to identify fracture healing. The time of fracture healing and postoperative complications of the four groups were compared. One year after the operation, knee function was evaluated by Bostman’s score.Results:During the study period, 168 patients with patellar fractures were treated by operations, and 88 patients were excluded because the fracture type did not meet the requirements or because there were combined fractures of the distal femur or tibial plateau. As a result, 80 patients were included in this study, 20 in each group. All the patients were followed up for an average period of 12.2 months. Compared with Group A, patients in Group D presented less postoperative discomfort in the prepatellar region, quicker fracture healing, less fixation failure and better postoperative knee function scores (all p < 0.05). The incidence of internal fixation failure in Group (B+D) was lower than that in Group (A+C) (p > 0.05).Conclusion:The "0" wire fixation system combined with a double-head cannulated compression screw seems to be more beneficial than the other three fixation systems for the treatment of transverse patellar fractures.

  • 标签: Transverse patellar fractures "0"fixation system Double-head cannulated compression screw
  • 简介:AbstractPurpose:Hemodynamically unstable patients with pelvic fractures still represent a challenge to trauma surgeons and have a very high mortality. This study was designed to explore the effect of the interventions of direct preperitoneal pelvic packing for the hemodynamically unstable pelvic fractures.Methods:This retrospective study enrolled 67 cases of severe pelvic fractures with unstable hemodynamics from October 2011 to December 2019. All patients presented in our emergency center and received preperitoneal pelvic packing were included in this study. The indication was persistent systolic blood pressure ≤90 mmHg during initial resuscitation and after transfusion of two units of red blood cells. Patients with hemodynamic stability who need no preperitoneal pelvic packing to control bleeding were excluded. Their demographic characteristics, clinical features, laboratory results, therapeutic interventions, adverse events, and prognostic outcomes were collected from digital information system of electronic medical records. Statistics were described as mean ± standard deviation or medium and analyzed using pair sample t-test or Mann-Whitney U-test.Results:The patients’ average age was 41.6 years, ranging from 10 to 88 years. Among them, 45 cases were male (67.2%) and 22 cases were female (32.8%). Significant difference was found regarding the systolic blood pressure (mmHg) in the emergency department (78.4 ± 13.9) and after preperitoneal pelvic packing in the surgery intensive care unit (100.1 ± 17.6) (p < 0.05). Simultaneously, the arterial base deficit (mmol/L) were significantly lower in the surgery intensive care unit (median -6, interquartile range -8 to -2) than in the emergency department (median -10, interquartile range -14 to -8) (p < 0.05). After preperitoneal pelvic packing, 15 patients (22.4%) underwent pelvic angiography for persistent hypotension or suspected ongoing haemorrhage. The overall mortality rate was 29.5% (20 of 67).Conclusions:Preperitoneal pelvic packing, as a useful surgical technique, is less invasive and can be very efficient in early intra-pelvic bleed control.

  • 标签: Pelvic fractures Preperitoneal pelvic packing Haemorrhage shock Multidiscipline cooperation
  • 简介:AbstractPurpose:In the surgical treatment of paediatric forearm fractures, plate-screw and titanium elastic nails are used. During the transformation of ligamento-osseous structures from adolescence form into adult form, more stable fixation is required. The aim of this study was to evaluate the results of locked intramedullary nail fixation in adolescent forearm fractures.Methods:A retrospective examination was made on 36 adolescent patients who underwent surgery with locked intramedullary nail fixation due to a forearm fracture. The included patients were in the adolescent age group (12-17 years), did not meet conservative follow-up criteria and had unstable fractures (>10° angulation and <50% cortex continuity after plaster casting). Patients were excluded from the study if they were aged >18 years or <12 years, had Gustilo-Anderson type 2/3 open fractures, multi-trauma, history of physeal injuries or could not be contacted during follow-up. Patients’ age, gender, body mass index, affected side, and the pronation and supination values during follow-up were noted. Functional evaluation of the patients was performed with disabilities of the arm, shoulder and hand score and the surgical outcomes were evaluated according to the Price criteria. The time to union, infection during follow-up, re-fracture and vascular nerve damage were also examined. Data were analyzed using SPSS 22 Windows package program software.Results:The patients comprised 30 males and 6 females (ratio, 5:1) with a mean age of (14.7 ± 2.1) years (range, 12-18 years). According to the Price criteria, the results of 33 patients were excellent, 3 were good and there were no moderate or poor cases. The mean disabilities of the arm, shoulder and hand score was 11.2 ± 6.1 (range, 4-28). The mean time to union was (8.7 ± 2.2) weeks (range, 6-14 weeks), while patients aged >15 years had prolonged time to union ([11.1 ± 1.8] weeks). There were no non-unions, re-fractures or infections. No complications were observed during implant removal. None of the patients had sensorial radial nerve injury or tendon damage.Conclusion:The locked intramedullary nailing technique, which is minimally invasive and provides biological fixation, was found to be successful and safe in the treatment of adolescent forearm fractures.

  • 标签: Adolescent forearm fracture Intramedullary locked nail Functional results Complications
  • 简介:

  • 标签:
  • 简介:AbstractPurpose:Treatment of irreducible femoral intertrochanteric fractures often requires open reduction. However, the technique unavoidably causes patients to suffer greater trauma. As such, minimally invasive techniques should be employed to reduce the surgical-related trauma on these patients and maintain a stable reduction of the fractures. Herein, a minimally invasive wire introducer was designed and used for the treatment of femoral intertrochanteric fractures. The effectiveness of using a wire-guided device to treat irreducible femoral intertrochanteric fractures was evaluated.Methods:Between 2013 and 2018, patients with femoral intertrochanteric fractures who were initially treated by intramedullary nail fixation but had difficult reduction using the traction beds were retrospectively reviewed. Decision for an additional surgery was based on the displacement of the fracture. The patients were then divided into two groups: those in the control group received an open reduction surgery while those in the observation group received a closed reduction surgery using a minimally invasive wire introducer to guide the wire that could assist in fracture reduction. The operation time, blood loss, visual analogue scale scores, angulation, reduction, neck-shaft angle, re-displacement, limb length discrepancy, and union time were then recorded and analyzed to determine the efficiency of the wire introducer technique. Categorical variables were analyzed by using Chi-square test, while continuous variables by independent t-test and the Mann-Whitney test accordingly.Results:There were 92 patients included in this study: 61 in the control group and 31 in the observation group. There were no significant differences in baseline demographic factors between the two groups. All surgeries were successful with no deaths within the perioperative period. The average follow-up time for the patients was 23.8 months. However, the observation group had a significantly shorter operation time, lower visual analogue scale score, less intraoperative bleeding, and shorter fracture healing time. There were no significant differences in the angulation, reduction, neck-shaft angle, and limb length discrepancy between the two groups.Conclusion:The minimally invasive wire guide achieved a similar effect to that of open reduction in the treatment of intertrochanteric fractures with difficult reduction. Moreover, the minimally invasive wire introducer is a good technology that accurately guides the wire during reduction. Indeed, it is an effective technique and achieves good clinical outcomes in restoration of irreducible femoral intertrochanteric fractures.

  • 标签: Femoral fractures Hip fractures Bone wires Minimally invasive surgical procedures
  • 简介:AbstractPurpose:Impending compartment syndrome is a common event following closed tibia fractures, which can progress to sinister compartment syndrome. Fasciotomy is the only definitive treatment available, though it has its own drawbacks and complications. Medical management at present consists of limb elevation and adequate hydration. This study aims at determining whether intravenous administration of Mannitol reduced the intracompartmental pressure in patients with closed tibial fractures.Methods:This is a double blinded, randomized control trial done in a single tertiary care center in India. Forty-five patients were recruited between February 2012 and October 2012. Forty patients who presented to the emergency department with isolated, closed, high velocity, and proximal 2/3 tibia fractures were included in this study. Patients with contraindication to Mannitol were excluded. They were allocated into 2 groups by the investigator using computer generated randomization. The pressure in the anterior compartment of the leg was measured with a handheld Stryker pressure monitor. Then either 20% Mannitol or 0.9% normal saline as given intravenously in a blinded manner, based on the randomization. The intracompartmental pressure was measured at 0, 1 and 3 h after the infusion. The participant, investigator and statistician were masked to the group assessment.Results:There was no difference in intracompartmental pressures at 1 or 3 h, between the groups. However, in patients with the baseline of compartmental pressures ≥30 mmHg, Mannitol showed a marked reduction in pressure of 8.5 mmHg at 1 h compared to almost no change in pressure in the saline group. There were no adverse events with the use of Mannitol.Conclusions:This preliminary study appears to show that Mannitol is useful in the management of the increased compartment pressure. The limitations of this study were that it only involved a small group of patients and the baseline pressures in both the groups were not comparable. More studies are required before the use of Mannitol as a standard of care in the management of compartment syndrome can be established.

  • 标签: Mannitol Compartment pressures Acute tibial fractures
  • 简介:AbstractRib fracture is the most common injury in chest trauma. Most of patients with rib fractures were treated conservatively, but up to 50% of patients, especially those with combined injury such as flail chest, presented chronic pain or chest wall deformities, and more than 30% had long-term disabilities, unable to retain a full-time job. In the past two decades, surgery for rib fractures has achieving good outcomes. However, in clinic, there are still some problems including inconsistency in surgical indications and quality control in medical services. Before the year of 2018, there were 3 guidelines on the management of regional traumatic rib fractures were published at home and abroad, focusing on the guidance of the overall treatment decisions and plans; another clinical guideline about the surgical treatment of rib fractures lacks recent related progress in surgical treatment of rib fractures. The Chinese Society of Traumatology, Chinese Medical Association, and the Chinese College of Trauma Surgeons, Chinese Medical Doctor Association organized experts from cardiothoracic surgery, trauma surgery, acute care surgery, orthopedics and other disciplines to participate together, following the principle of evidence-based medicine and in line with the scientific nature and practicality, formulated the Chinese consensus for surgical treatment of traumatic rib fractures (STTRF 2021). This expert consensus put forward some clear, applicable, and graded recommendations from seven aspects: preoperative imaging evaluation, surgical indications, timing of surgery, surgical methods, rib fracture sites for surgical fixation, internal fixation method and material selection, treatment of combined injuries in rib fractures, in order to provide guidance and reference for surgical treatment of traumatic rib fractures.

  • 标签: Flail chest Injury Trauma Thoracic Traumatic rib fracture Surgical stabilization of rib fractures
  • 简介:AbstractTwo cases of type II odontoid fractures were reported to share our experience in surgery treatment of such cases. A 33-year-old woman with comminuted type II odontoid fracture and a 42-year-old man with fracture end hardened type II odontoid fracture received surgical treatment in our hospital. Though imaging examination suggested that these two patients were suitable for anterior screw fixation, we encountered difficulties during the operation. The two patients eventually underwent posterior C1-C2 fusion surgery and recovered well. According to the experience of these two cases, we found that the fracture line angle and the degree of comminution are two important factors affecting surgical decision-making. Although anterior screw fixation is the ideal choice for type II odontoid fractures with anterior superior to posterior inferior fracture line, it may not be the best choice for comminuted or fracture end hardened type II odontoid fractures.

  • 标签: Bone screws Fracture fixation Odontoid fracture
  • 简介:AbstractPurpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment. This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation.Methods:A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups: volar plate group and external fixator group. These patients aged between 18 and 60 years had unilateral fractures, and agreed to be included in the study. Patients with a history of fracture, bilateral fracture, associated other injuries, delayed injury for more than 2 weeks, open fracture, pre-existing arthrosis or disability, psychiatric illness and pathological fracture were excluded. Patients were followed up at 6 weeks, 3 months, 6 months and 1 year. The assessment of pain, functional activity, range of motion and grip strength was done at each stage of follow-up. The pain and functional activities were assessed by patient rated wrist evaluation (PRWE) score and disabilities of the arm, shoulder and hand (DASH) score.Results:Patients in volar plate group had superior PRWE score and DASH score at each stage of follow-up. At 1 year follow-up, the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group; while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group. They had better flexion and extension range of movement. They also had better pronation and supination range of motion at initial follow-up, however the difference get attenuated by 1 year. Volar plate group had significantly better grip strength than external fixator group. Complication rates were higher in external fixation group.Conclusion:Fixation with variable angle volar plate results in early wrist mobilization, better range of movement, less pain and disability and early return of function.

  • 标签: Comminuted Distal radius fracture Intraarticular Volar plate External fixator
  • 简介:AbstractPurpose:This meta-analysis compared the clinical outcome of three-dimensional (3D) printing combined with open reduction and internal fixation (ORIF) to traditional ORIF in the treatment of acetabular fractures.Methods:We searched the Cochrane Library, PubMed, Embase, VIP database, CNKI, and Wanfang data-base with keywords "acetabular fracture" , "3D printing" , "three-dimensional printing" , "open reduction and internal fixation" , "Acetabulum" , "Acetabula" from January 2000 to March 2020. Two reviewers independently selected articles, extracted data, assessed the quality evidence and risk bias of included trials using the Cochrane Collaboration’ s tools and/or Newcastle-Ottawa scale. When the two analysts had different opinions, they would ask the third analyst for opinion. Randomized controlled trials or retrospective comparative studies of 3D printing combined with ORIF (3D printing group) versus traditional ORIF (conventional group) in the treatment of acetabular fractures were selected. The data of operation time, intraoperative blood loss, intraoperative fluoroscopy times, incidence of complications, excellent and good rate of Matta score for reduction, and excellent and good rate of hip function score were extracted. Stata14.0 statistical software was used for data analysis.Results:Altogether 9 articles were selected, including 5 randomized controlled trials and 4 retrospective studies. A total of 467 patients were analyzed, 250 in the conventional group, and 217 in the 3D printing group. The operation time in the 3D printing group was less than that in the conventional group and the difference was statistically significant (standardized mean difference (SMD) =-1.19, 95% CI:-1.55 to-0.82, p < 0.05). The intraoperative bleeding volume of the 3D printing group was significantly lower than that of the conventional group (SMD=-1.08, 95% CI:-1.65 to-0.51, p < 0.05). The fluoroscopy times were less in the 3D printing group than in the conventional group and the difference was statistically significant (SMD=-1.64, 95% CI:-2.35 to-0.93, p < 0.05). The total incidence of complications in the 3D printing group was significantly lower than that in the conventional group (OR = 0.43, 95% CI: 0.24-0.79, p < 0.05). There was no significant difference in the excellent and good rate of Matta score for reduction between the two groups (OR = 0.60, 95% CI: 0.34-1.06, p > 0.05). There was no significant difference in the excellent and good rate of hip function score at the end of postoperative follow-up between the two groups (OR = 0.84, 95% CI: 0.46-1.56, p > 0.05), but the follow-up time varies from 6 months to 40 months.Conclusion:Compared with traditional ORIF, 3D printing combined with ORIF has certain advantages in terms that 3D printing not only helps surgeons to understand acetabular fractures more intuitively, but also effectively reduces operation time, intraoperative blood loss, intraoperative fluoroscopy times, and postoperative complications. However, there were no significant differences in the excellent and good rate of Matta score for reduction and the excellent and good rate of hip function score at the end of follow-up.

  • 标签: Three-dimensional printing Acetabular fractures Open reduction and internal fixation Meta-analysis