学科分类
/ 25
500 个结果
  • 简介:摘要:短路故障电流危害巨大,目前断路的遮断容量已经不能满足系统的需求,将短路故障电流限制在已有断路的遮断容量以内,才能保证系统安全运行。同时,传统限流电抗又存在损耗过大、电磁污染等问题,急需一种更先进节能的替代产品,因此新型故障限流的研究就显得尤为必要。本人就节能型故障限流的结构及特点进行了简要的分析,并对快速开关型故障限流的关键技术进行的详细的介绍,希望给相关人士一些启示。

  • 标签: 快速开关 节能型 故障限流器关键技术
  • 简介:摘要:当前城市中心区配电网越来越难以满足日益增长的电力负荷及高质量供电的要求,亟需研究新技术的应用以解决问题。本文介绍了超导输电系统的构成、特点及其在电网中的应用。高效率、低损耗和大容量电力输送的超导输电系统将为城市配电网所面临的挑战提供一种可行的解决方案。

  • 标签: 超导电缆 超导输电系统 电网
  • 简介:【摘要】随着随着电动汽车和风光储能的逐渐推广,对现有配电网的负荷接入方式和潮流调节提出了更为灵活、更为严苛的要求,而 限流式统一潮流控制(简称限流式 UPFC)是一种结合 UPFC和桥式限流,能有效应对系统短路故障的新型柔性交流输电装置 , 在未来的交直流混合微网中有较好的应用前景 。本文提出了 10kV限流式 UPFC的工作原理,明确了 UPFC模块和限流模块的工作方式,为解决日后交直流混合 配电 网即将遇到的调节与限流问题提供了一种思路。

  • 标签: 交直流混合 配电网 限流式 UPFC UPFC模块 限流器模块
  • 简介:摘要目的分析门静脉限流联合肝动脉结扎对Sprague Dawley(SD)大鼠肝再生与肝损伤的影响。方法健康清洁级SD雄性大鼠24只,250~280 g,7~8周龄,采用随机数字表随机分为门静脉结扎(PVL)组、轻度限流组和中度限流组,每组各8只。PVL组结扎大鼠门静脉右叶支、尾叶支及左侧支,仅保留门静脉右侧支。轻度限流组和中度限流组操作同PVL,但门静脉左侧支轻度、中度限流,同时结扎肝动脉左侧支。术后72 h留取肝左中叶行HE染色并计算总坏死分数、肝右中叶行Ki-67免疫组化染色并计数阳性细胞数,计算肝右中叶肝再生率,检测血清肝功能指标。结果肝右中叶肝再生率PVL组为(109.1±10.9)%,中度限流组(105.0±12.3)%,均明显高于轻度限流组(67.1±6.4)%,差异均有统计学意义(均P<0.05)。肝右中叶Ki-67免疫组化染色结果与肝再生率结果一致。肝左中叶总坏死分数中度限流组4.50(3.25,6.00)分、PVL组2.00(1.25,3.00)分、轻度限流组0(0,0.75)分,三组总坏死分数呈降低趋势,差异均有统计学意义(均P<0.05)。轻度限流组丙氨酸氨基转移酶为(48.4±11.4)U/L,明显低于PVL组(67.2±12.2)U/L和中度限流组(74.3±14.2)U/L,差异均有统计学意义(均P<0.05)。三组天冬氨酸氨基转移酶、白蛋白以及总胆红素比较差异均无统计学意义(均P>0.05)。结论适当的门静脉限流联合肝动脉结扎能够有效诱导SD大鼠预留侧肝组织再生,同时控制阻塞侧肝组织损伤。

  • 标签: 门静脉 肝动脉结扎 肝再生 肝损伤
  • 简介:摘要:调相机在电网运行中提供动态无功补偿,对于电网的稳定运行有着重要的作用。目前,一台 300kvar级高温超导调相机样机正在研制,由于其工作转速 1500rpm,需要对各个重要部件进行振动分析,以防出现危险。多场输入部件是超导电机转子进行冷却和强弱电通流的重要结构,文章对样机的多场输入部件进行了振动特性分析,在静止、正常工作、超速工作三个工况下分别计算了多场输入部件的模态结果。根据仿真计算结果,分析在实际运转中小样机是否有进入模态发生共振的危险,以及在样机实际工作时规避与模态阶数相近的外界扰动,确保小型样机能够正常工作,为未来 10Mvar级调相机的研制积累宝贵的设计经验。

  • 标签:
  • 简介:摘要

  • 标签:
  • 简介:摘要:目的:本文主要通过对1.5T超导MRI诊断膝关节隐匿性骨折的临床护理效果进行分析研究。方法:本文主要选自2018年9月至2019年9月期间,在我院接收护理治疗的60例膝关节隐匿性骨折患者为研究对象,并且医护人员通过对60例膝关节隐匿性骨折患者随机分为两组,分别为对照组和观察组,每组各30例患者。医护人员通过对对照组患者采用的是64排螺旋CT进行检查诊断,而对观察组患者采用的是1.5T超导MRI方式进行检查诊断。其中,1.5T超导MRI方式进行检查方法中,存在着三种序列,分别为T1WI序列、T2WI序列以及STIR序列,每种序列上的影像信号将会代表着不同隐匿性骨折症状。医护人员通过对两组患者的骨折检出率进行对比分析。结论:医护人员通过对两组患者的骨折检出率进行对比分析后可以发现,对照组患者的检出率达到73.33%,而观察组患者的T1W1检出率达到86.67%,T2W1检出率达到93.33%。通过调查数据可以看出来,观察组患者的检出率明显高于对照组患者,具有明显差异,符合统计学意义(P

  • 标签: 1.5T超导MRI 64排螺旋CT 膝关节 隐匿性骨折
  • 简介:  摘要:目的 探讨超导可视系统联合米索前列醇在无痛人流中的应用效果。方法 选取 2012年 4月~ 2015年 5月我站收治的 80例行早早孕无痛人流术患者。随机分成两组,每组 40例,对照组行常规无痛人流术,观察组术前含服米索前列醇,在超导可视系统引导下完成手术,对比两组手术情况及并发症情况。结果 观察组手术时间、术中出血量、宫颈扩张总有效率及并发症发生率明显优于对照组( 2.10±0.40vs3.95±0.78, 4.96±1.38vs13.67±1.60, 95.0%vs67.5%, 2.5%vs27.5%), P<0.05,有统计学意义。结论 超导可视系统联合米索前列醇在无痛人流术中的应用可显著提高手术效果,减少并发症的发生,值得进一步推广。    关键词:超导可视系统;米索前列醇;早早孕;无痛人流;效果     Abstract: Objective To investigate the effect of superconducting visual system combined with misoprostol in painless abortion. Methods from April 2012 to may 2015, 80 patients with painless abortion in early pregnancy were selected. They were randomly divided into two groups, 40 cases in each group. The control group was given routine painless abortion, and the observation group was given misoprostol before operation, and the operation was completed under the guidance of superconducting visual system. The operation and complications of the two groups were compared. Results the operation time, bleeding volume, total effective rate of cervical dilatation and the incidence of complications in the observation group were significantly better than those in the control group (2.10 ± 0.40 vs 3.95 ± 0.78, 4.96 ± 1.38 vs 13.67 ± 1.60, 95.0% vs 67.5%, 2.5% vs 27.5%), P < 0.05, with statistical significance. Conclusion the application of superconducting visual system combined with misoprostol in painless induced abortion can significantly improve the surgical effect and reduce the incidence of complications, which is worthy of further promotion.

  • 标签:
  • 简介:摘要:介绍了一种新型的光子环形来实现射频系统的同时收发。 阐述了光子环形实现收发隔离的工作原理。采用微波腔模型分析了基于 MZ调制的光子环形的隔离度,并基于商用的马赫 -曾德尔电光调制对光子环形隔离性能进行了实验验证。

  • 标签: 光子环形器 马赫 -曾德尔调制器 隔离度
  • 简介:摘要 :变压是电力系统中的重要组成元件,其冷却渗漏油除了不利于变压的安全稳定运行之外,还会引起环境污染,甚至造成国民经济的损失。本文主要分析了变压冷却渗漏油现象及原因,并且提出了相关的处理对策,以及设计开发出一款冷却排气阀渗油处理专用工具,希望以此能够有效处理及控制变压渗漏油缺陷。

  • 标签: 变压器 冷却器 渗漏油 处理对策
  • 简介:摘 要 为了快速进行谐波减速的可靠性寿命试验,制作了一套谐波减速加速寿命测试系统。通过试验数据进行分析统计,从而得出输出转速、输出转矩对谐波减速寿命的影响,验证试验系统的合理性与可行性。

  • 标签:
  • 简介:摘要:电力资源是人们生活中不可或缺的能源,电力输送的质量和效率直接影响着社会经济的发展和人们的生产生活,近年来电力部门对用电安全问题引起了足够的重视,严格按照相关规定和制度,落实了对电力运行设备的维护和保养工作。变压的运行质量是电力系统安全稳定运转的关键,因此必须全力保护其在使用过程中不受到各种因素的影响和破坏,保证安全高效的电力供应。文章主要围绕对电力变压冷却的运行故障及处理技术进行分析。

  • 标签: 电力变压器 冷却器 故障 处理技术
  • 简介:摘要:本文分析了 PEDC的控制方案,该方案通过控制 PEDC开门信号、关门信号、关闭锁紧信号和奇数偶数门使能信号等来实现对 PEDC的功能测试 ,并且设计了以STM32为主控芯片的测试仪器 PEDC屏蔽门控制信号发生,并开发了程序,模拟 PSC控制信号,控制 PEDC控制进行了开关门动作。通过线上测试,可以在实际现场进行屏蔽门的开关门操作,在一定程度上解决了人工需要接线等繁杂程序。

  • 标签: PEDC 线上测试 信号发生器
  • 简介:

  • 标签:
  • 简介: 摘要:变压作为电力企业非常重要的设备之一,其安装质量会直接影响到变压运行的安全。变压安装是一项十分系统的工程,工序较为复杂,任何一个环节出现问题都会对安装质量带来较大的影响,因此在变压安装过程中,需要对关键工序进行掌握,并对安装过程中容易出现的问题进行重点关注,有效地避免安全过程中质量缺陷产生,确保变压运行的安全性和可靠性。 

  • 标签:   变压器 安装质量 安全运行 影响 
  • 简介:摘要 : 随着我国经济发展进一步繁荣,电力作为一种清洁能源在我国能源消耗比重中占有很大比例,因此电力行业的稳定性将直接影响的经济的平稳运行。 变压与电压互感在我们生活中都是十分常见的两种电气设备 ,二者虽然工作原理和结构上很大程度上的相同,但二者容量、用途上又有很大区别。部分刚刚接触电力行业的从业人员对于二者的区别没有一个清晰的认识,因此本文围绕变压与电压互感的区别展开分析,希望能够提供有益借鉴。

  • 标签: 变压器 电压互感器 区别
  • 简介:摘要:在现实生活中,随着生活节奏加快,大多数人都曾有过健忘、疏忽、被窃等原因造成的贵重物品丢失的经历。因此,防丢的出现可以有效防范这些意外的发生。本设计由STC15W408AD单片机、NRF24L01无线传输模块和电源模块组成。当发射离开接收一定距离之后,接收工作进行报警,发出报警声,提示使用者。无线防丢器具有可靠性高,稳定性优异,功耗低,使用方便,价格低廉等特点。

  • 标签: