摘要
Basedonalargeamountofdissectionatweldedinterfaceandquantitativemicroscopicexaminationofweldedrate,thesuitablelimitgreyscalevaluewasdetermined,andtheweldedrateofsuperplasticsolid-stateweldinginterfaceofheterogeneoussteelwassystematicallystudiedbymeansofself-madeultrasonicC-scanningimaginginspectionsystem.Theexperimentalresultsshow:theweldedstateofsuperplasticsolid-stateweldinginterfaceofheterogeneoussteelcanbeconductedtobemoreaccurately,reliablyandquicklyinspectedbymeansofthissystem,andtheultrasonictestingresultsaregoodconsistentwithactualexaminationresultsoftheinterfacedefectivedistribution.Withintheextentofthesuitbleweldedrate,theweldedratein40Cr/T10Asuperplasticweldingprocesstestedbythissystemislinearwithitstensilestrengthofjoint.