简介:摘要:本文简要介绍了同步热分析(STA)技术的基本原理及发展历史,并应用NETZSCH公司生产的差热分析仪对几种典型钛合金β相转变温度及几种典型铝合金的过热过烧温度进行了简要测试,并对差热分析仪的测试条件及影响因素做了一定的研究。
简介:AbstractBackground:Superficial temporal artery (STA)-middle cerebral artery (MCA) bypass surgery is now being widely used in moyamoya disease, and its therapeutic value in SICAO remains divergent.Methods:A systematic search was performed in PubMed, EMBASE, and Cochrane Databases in Feb. 2020 and updated in Jun. 2019. We have strict inclusion and exclusion criteria. Cochrane Bias Risk Assessment Tool was used to assess the quality of included RCTs. Review Manager 5.3 was used for analysis results in terms of comparing the STA-MCA bypass and BMT. For dichotomous variable outcomes, risk ratios (RRs) and 95% confidence intervals (95%CIs) were calculated for the assessment.Results:The total patient cohort consisted of 2419 patients, of whom 1188 (49.1%) patients had been grouped in STA-MCA bypass and 1231 (50.9%) patients had been divided into the BMT group. Mean follow-up of included patients was 29 months. The RR of the seven studies was 1.01, and the 95% confidence interval was .89-1.15, with statistical significance, Z = .13, P = .89, sustaining that STA-MCA bypass was not superior to BMT in symptomatic carotid artery occlusion disease.Conclusions:STA-MCA bypass and BMT were associated with similar rates of a composite of long-term stroke. And the risk of long-term overall stroke was mildly higher with BMT. At present, each patient should receive more precise treatment, by reasonably assessing the individual differences of each patient to reduce the recurrence rate of stroke.
简介:摘要:现如今,我国的经济在迅猛发展,社会在不断进步,人们的生活质量在不断提高,对于电力的需求在不断加大,利用1000kV特高压变电构架在均匀流、A类和B类地貌高频底部测力天平风洞试验同步测量的基底弯矩和反力的时程数据,对变电构架整体及节段模型的气动力系数功率谱以及均值、均方根、峰度和偏度等统计特性对比分析,详细考察风向、地貌等因素对风荷载特性的影响规律并探讨不同流场下输电构架整体与节段模型的气动力特性比例关系。研究结果表明:以A节段模型为例,0o风向均匀流场、A类和B类地貌下Cx均值和均方根值之比分别为1:1.58:1.57和1:1.60:1.59,与之对应,Cy均值和均方根值之比分别为1:7.0:7.57和1:1.53:1.30。整体和各节段模型对比分析发现,90o风向均匀流场下整体模型与四个节段模型Cx的均值和均方根值之比分别为1:0.02:0.26:0.22:0.38和1:0.06:0.37:0.32:0.41,Cy的均值和均方根值之比分别为1:0.46:0.57:0.43:0.69和1:0.47:0.58:0.44:0.70。基于时域和频域的综合对比分析明确1000kV特高压变电构架的最不利风向角以及设计风荷载的取值,为工程设计提供参考。
简介:摘 要:该厂锅炉采用的是中速磨煤机一次风正压直吹式制粉系统,配置6台CS2036HP 型电子称重式给煤机、6台HP1163中速磨煤机,1台给煤机对应1台磨煤机,给煤机采用变频器进行调速。在机组投产初期,由于给煤机供电电源故障,导致了机组MFT保护动作停机事故,其后给煤机供电电源进行了多次改造优化,充分提高了给煤机运行的可靠性。
简介:摘要:现如今,我国的经济在迅猛发展,社会在不断进步,人们的生活质量在不断提高,对于电力的需求在不断加大,利用1000kV特高压变电构架在均匀流、A类和B类地貌高频底部测力天平风洞试验同步测量的基底弯矩和反力的时程数据,对变电构架整体及节段模型的气动力系数功率谱以及均值、均方根、峰度和偏度等统计特性对比分析,详细考察风向、地貌等因素对风荷载特性的影响规律并探讨不同流场下输电构架整体与节段模型的气动力特性比例关系。研究结果表明:以A节段模型为例,0o风向均匀流场、A类和B类地貌下Cx均值和均方根值之比分别为1:1.58:1.57和1:1.60:1.59,与之对应,Cy均值和均方根值之比分别为1:7.0:7.57和1:1.53:1.30。整体和各节段模型对比分析发现,90o风向均匀流场下整体模型与四个节段模型Cx的均值和均方根值之比分别为1:0.02:0.26:0.22:0.38和1:0.06:0.37:0.32:0.41,Cy的均值和均方根值之比分别为1:0.46:0.57:0.43:0.69和1:0.47:0.58:0.44:0.70。基于时域和频域的综合对比分析明确1000kV特高压变电构架的最不利风向角以及设计风荷载的取值,为工程设计提供参考。
简介:摘要:大唐东营发电公司地处东营港经济开发区,在役两台百万千瓦燃煤发电机组,是《山东省半岛蓝色经济区发展规划》和《黄河三角洲高效生态经济区发展规划》重点能源项目。两台机组分别于2020年11月11日、12月16日投入商业运行,是世界首台“六缸六排汽”百万千瓦机组,入选国家能源局第一批能源领域首台(套)重大技术装备项目。东营公司地处公路交通末端,铁路是最主要的来煤和保供通道,东营公司年度发电量计划完成74.4亿千瓦时,燃用煤炭近400吨。如何在当前复杂的燃料供应市场发挥自己的作用?是解决当前公司生存和发展的一个重要课题,为实现燃料保供目标,建立以保障供应为前提,降控煤价为重点,市场调研为抓手,科学调运为手段的燃料管理模式。
简介:摘 要:本文针对QB厂国产1000MW 汽轮机通流改造后在运行过程中轴系振动大的情况,通过对轴系振动异常时汽机相关参数进行分析讨论,确定振动故障类型为蒸汽激振,经过一系列试验操作及检修工作,现场实施后对控制蒸汽激振取得较好效果,为今后同类型机组类似故障处理提供有益借鉴。
简介:摘要:空预器的运行状况对锅炉的安全和经济运行有着重大影响,空预器的堵塞问题一直存在,特别是在加装脱硝后,堵塞情况更加严重。因此,怎么有效减少空预器堵塞是各大火电机组积极探索的方向。